Output Power:30kW

Peak Efficiency:96.2%

Full Load Noise:≤65dB(at 20℃)

Warranty Period:5year

 

Features

 

1.A mature topology structure coupled with comprehensive protection strategies ensures stability;

2.Full front potting enhances stronger environmental adaptability;

3.With cumulative applications exceeding 100,000 units, there is ample application support. 

Input

Voltage Range
260-456Vac
Current Range
0~58A
Wiring
Three Phase, 3W+PE
Frequency
50/60Hz
THDi
3% max Under Nominal Power
Power Factor
≥0.99 @full load
Standby Power Consumption
7W max
Start-up Current Surge
≤110% rated max current

Output

Voltage Range
50~1000Vdc
Nominal Power
30kW at 300-1000Vdc
Max Current
100A
Short Circuit Protection
Current limit when in output short circuit, auto recovery
Voltage Regulation
Within +/- 0.5%
Current Regulation
Within +/- 1%
Voltage Ripple
≤ 1%
Start-up Voltage Surge
≤ 105% of the setting value

Communication & Alarm

Communication
CAN
Parallel Installation
60 Modules max.
Module Address
Support software setting and hardware setting

Environment

Operation Temp.
-40℃~+75℃ (derating from 55℃ to 75℃)
Storage Temp.
-40℃~+85℃
Relative Humidity 
Under 98% RH, non-condensing
Altitude
Under 2000m with nominal power
Corrosion Resistance
Operation shall be free from harmful gases or conductive media that could corrode metals or damage insulation

General Spec.

Dimension
350*390*84(W*D*H, mm, w/o handle)
Weight
Under 17kg
IP Protection
IP20
Cooling
Forced Air Cooling
Efficiency
≥ 95% @full load, peak efficiency of 96.2%
Noise
Under 65dB at full load @ 25℃
EMI Compliance
Class A
ID Setting
software setting or pre-set via dialer
OTA
/

Protection

Temperature Protection
automatically shuts down when temperatures exceed 75℃ and reverts to standby mode once normal temperatures are restored
Input OVP, UVP, phase lose
automatically shuts down in the event of abnormal input voltage and returns to standby mode when input conditions normalize.
Over Current, Short Circuit
manually restart following an automatic shutdown
Output Over Voltage
protection settings through software or utilize built-in hardware

What cooling method does the charging module use (air-cooled/liquid-cooled)? Can it operate stably in harsh environments such as high temperature and high humidity?

30/40kw charging module features forced air cooling, and the 60kw one features independent air-duct cooling. XY Power charging module is widely known as its reliability and efficiency, it’s market-proven to operate stably in harsh environments. Comparing with these two modules, the independent air-duct cooling module is rated IP65 and it has better adaptability to high temperature and high humidity.

What is the expected lifespan of the charging module? Does it require regular maintenance? If so, what is the frequency and approximate cost of maintenance?

The lifespan of a charging module is influenced by the longevity of several key components, primarily including fans, film capacitors, electrolytic capacitors, and others. XY Power intelligent operation and maintenance functionality enables the prediction and balancing of the lifespan of these critical components. This ensures higher reliability, extended lifespan, lower maintenance costs, and more precise operation and maintenance management throughout the entire lifecycle of the charging infrastructure.

Does the charging module support smart features such as remote monitoring, fault diagnosis, and OTA updates? Is it compatible with mainstream communication protocols like CAN?

Absolutely yes. Starting from the X2 generation, the charging modules from XY Power are equipped with an intelligent operation and maintenance system. These modules can upload more data through protocols, providing data and functional support for the intelligent operation and maintenance of charging stations or platforms. This enhances the overall reliability, extends the lifespan, reduces maintenance costs, and enables more precise operation and maintenance management throughout the entire lifecycle of the charging facilities.
The intelligent operation and maintenance system by XY Power can achieve lifespan prediction, fault warning, grid monitoring, environmental sensing, and system auxiliary functions.

XY Power is pleased to offer you expert system development, product technology, and comprehensive lifecycle maintenance services.

We warmly welcome you to reach out to us.

previous page

next page

previous page

next page


Related Products

X40133Q1E

XY Power Highly Competitive Charging Module

X60200B1-IP65

XY Power High Power Low noise charging module-IP65

Search historyClear all records
Up to 8 historical search records can be displayed~
All
  • All
  • Product Management
  • News
  • Introduction
  • Enterprise outlets
  • FAQ
  • Enterprise Video
  • Enterprise Atlas